{"title":"Regular Breakers","description":"","products":[{"product_id":"square-d-hom250-50a-2-pole-breaker","title":"Square D HOM250 50 Amp 2-Pole Circuit Breaker, Homeline Double-Pole Plug-On 120\/240V","description":"\u003cp\u003eThe Square D HOM250 by Schneider Electric is a brand new 50 Amp, 2-pole, 120\/240V \u003cstrong\u003eHomeline plug-on circuit breaker\u003c\/strong\u003e. It's built for heavy 240V loads like electric ranges, subpanels, and EV chargers, with reliable thermal-magnetic protection against overloads and short circuits.\u003c\/p\u003e\n\u003ch3\u003ePower for Big Loads\u003c\/h3\u003e\n\u003cp\u003eElectric ranges, subpanels, and many Level 2 EV chargers need a 50A circuit. The HOM250 snaps straight onto the Homeline bus and handles these high-demand loads safely.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e50A, 2-pole (double-pole), 120\/240VAC\u003c\/li\u003e\n\u003cli\u003e10kA interrupting rating\u003c\/li\u003e\n\u003cli\u003eThermal-magnetic trip for overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003eHACR rated for heating, air conditioning, and refrigeration equipment\u003c\/li\u003e\n\u003cli\u003eCommon trip: both poles open together\u003c\/li\u003e\n\u003cli\u003ePlug-on mounting for Square D Homeline load centers\u003c\/li\u003e\n\u003cli\u003eUL Listed\u003c\/li\u003e\n\u003cli\u003eBrand new\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSize\u003c\/h3\u003e\n\u003cp\u003eTakes 2 spaces in a Square D Homeline load center.\u003c\/p\u003e\n\u003ch3\u003eUses\u003c\/h3\u003e\n\u003cp\u003eElectric ranges and cooktops, subpanels, Level 2 EV chargers, large A\/C units and heat pumps, and 50A RV or welder receptacles.\u003c\/p\u003e\n\u003ch3\u003eMost Common Use\u003c\/h3\u003e\n\u003cp\u003eElectric range circuits and garage or shop subpanels in homes with a Square D Homeline panel. For an EV charger, always follow the charger manufacturer's breaker requirement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e A 50A breaker must be used with properly sized wire, typically 6 AWG copper or larger. Check your wire type and local code.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e This breaker is designed for \u003cstrong\u003eSquare D Homeline load centers only\u003c\/strong\u003e. It does not fit Square D QO panels or panels from other brands. Check the label inside your panel door before ordering. If you're unsure, send us a photo of your panel label and we'll help you confirm the fit.\u003c\/p\u003e\n\u003ch3\u003eWhy Buy From Us\u003c\/h3\u003e\n\u003cp\u003eWith 24+ years of experience in the electrical industry, we know the products we sell and we're happy to answer your questions before you buy. Same-day handling, insured shipping, 30-day returns, and a 12-month warranty handled directly by us.\u003c\/p\u003e\n\u003ch3\u003eShipping\u003c\/h3\u003e\n\u003cp\u003eShips same day, carefully packaged and insured.\u003c\/p\u003e\n\u003ch3\u003eNote\u003c\/h3\u003e\n\u003cp\u003eInstallation should be performed by a qualified person in accordance with local codes. Always turn off the main breaker before working inside a panel.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":46717010706598,"sku":"HOM250","price":15.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0708\/1377\/8086\/files\/1.jpg?v=1759413804"},{"product_id":"eaton-br250-50a-2pole-circuit-breaker","title":"Eaton BR250 50 Amp 2-Pole Circuit Breaker, Type BR Double-Pole 120\/240V","description":"\u003cp\u003eThe Eaton BR250 is a brand new 50 Amp, 2-pole, 120\/240V \u003cstrong\u003eType BR plug-on circuit breaker\u003c\/strong\u003e for Eaton BR load centers. It's built for heavy 240V loads like electric ranges, subpanels, and EV chargers, with reliable thermal-magnetic protection against overloads and short circuits.\u003c\/p\u003e\n\u003ch3\u003ePower for Big Loads\u003c\/h3\u003e\n\u003cp\u003eElectric ranges, subpanels, and many Level 2 EV chargers need a 50A circuit. The BR250 snaps straight onto the panel bus and handles these high-demand loads safely.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e50A, 2-pole (double-pole), 120\/240VAC\u003c\/li\u003e\n\u003cli\u003e10kA interrupting rating\u003c\/li\u003e\n\u003cli\u003eThermal-magnetic trip for overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003eHACR rated for heating, air conditioning, and refrigeration equipment\u003c\/li\u003e\n\u003cli\u003eCommon trip: both poles open together\u003c\/li\u003e\n\u003cli\u003ePlug-on mounting for Eaton Type BR load centers\u003c\/li\u003e\n\u003cli\u003eUL Listed\u003c\/li\u003e\n\u003cli\u003eBrand new\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSize\u003c\/h3\u003e\n\u003cp\u003eTakes 2 spaces (1\" per pole) in an Eaton BR load center.\u003c\/p\u003e\n\u003ch3\u003eUses\u003c\/h3\u003e\n\u003cp\u003eElectric ranges and cooktops, subpanels, Level 2 EV chargers, large A\/C units and heat pumps, and 50A RV or welder receptacles.\u003c\/p\u003e\n\u003ch3\u003eMost Common Use\u003c\/h3\u003e\n\u003cp\u003eElectric range circuits and garage or shop subpanels in homes with an Eaton BR panel. For an EV charger, always follow the charger manufacturer's breaker requirement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e A 50A breaker must be used with properly sized wire, typically 6 AWG copper or larger. Check your wire type and local code.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e This breaker is designed for \u003cstrong\u003eEaton Type BR load centers\u003c\/strong\u003e. Check the label inside your panel door before ordering. If you're unsure, send us a photo of your panel label and we'll help you confirm the fit.\u003c\/p\u003e\n\u003ch3\u003eWhy Buy From Us\u003c\/h3\u003e\n\u003cp\u003eWith 24+ years of experience in the electrical industry, we know the products we sell and we're happy to answer your questions before you buy. Same-day handling, insured shipping, 30-day returns, and a 12-month warranty handled directly by us.\u003c\/p\u003e\n\u003ch3\u003eShipping\u003c\/h3\u003e\n\u003cp\u003eShips same day, carefully packaged and insured.\u003c\/p\u003e\n\u003ch3\u003eNote\u003c\/h3\u003e\n\u003cp\u003eInstallation should be performed by a qualified person in accordance with local codes. Always turn off the main breaker before working inside a panel.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":46726736838822,"sku":"BR250","price":19.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0708\/1377\/8086\/files\/57_7bbf0ea4-6779-49aa-aa56-71d54240a353.png?v=1759771204"},{"product_id":"eaton-br230-30a-double-pole-circuit-breaker","title":"Eaton BR230 30 Amp 2-Pole Circuit Breaker, Type BR Double-Pole 120\/240V","description":"\u003cp\u003eThe Eaton BR230 is a brand new 30 Amp, 2-pole, 120\/240V \u003cstrong\u003eType BR plug-on circuit breaker\u003c\/strong\u003e for Eaton BR load centers. It's the standard breaker for electric dryers and water heaters, with reliable thermal-magnetic protection against overloads and short circuits.\u003c\/p\u003e\n\u003ch3\u003eThe Dryer and Water Heater Breaker\u003c\/h3\u003e\n\u003cp\u003eMost electric dryers and standard electric water heaters run on a 30A, 240V circuit. The BR230 snaps straight onto the panel bus, so replacing a worn breaker or adding a new circuit is quick and clean.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e30A, 2-pole (double-pole), 120\/240VAC\u003c\/li\u003e\n\u003cli\u003e10kA interrupting rating\u003c\/li\u003e\n\u003cli\u003eThermal-magnetic trip for overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003eHACR rated for heating, air conditioning, and refrigeration equipment\u003c\/li\u003e\n\u003cli\u003eCommon trip: both poles open together\u003c\/li\u003e\n\u003cli\u003ePlug-on mounting for Eaton Type BR load centers\u003c\/li\u003e\n\u003cli\u003eUL Listed\u003c\/li\u003e\n\u003cli\u003eBrand new\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSize\u003c\/h3\u003e\n\u003cp\u003eTakes 2 spaces (1\" per pole) in an Eaton BR load center.\u003c\/p\u003e\n\u003ch3\u003eUses\u003c\/h3\u003e\n\u003cp\u003eElectric dryers, electric water heaters, A\/C condensers, heat pumps, and other 30A, 240V circuits.\u003c\/p\u003e\n\u003ch3\u003eMost Common Use\u003c\/h3\u003e\n\u003cp\u003eElectric dryer and water heater circuits in homes with an Eaton BR panel, or replacing a worn or faulty 30A 2-pole breaker.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e A 30A breaker must be used with 10 AWG copper wire or larger. Never install a 30A breaker on a circuit wired with 12 or 14 AWG wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e This breaker is designed for \u003cstrong\u003eEaton Type BR load centers\u003c\/strong\u003e. Check the label inside your panel door before ordering. If you're unsure, send us a photo of your panel label and we'll help you confirm the fit.\u003c\/p\u003e\n\u003ch3\u003eWhy Buy From Us\u003c\/h3\u003e\n\u003cp\u003eWith 24+ years of experience in the electrical industry, we know the products we sell and we're happy to answer your questions before you buy. Same-day handling, insured shipping, 30-day returns, and a 12-month warranty handled directly by us.\u003c\/p\u003e\n\u003ch3\u003eShipping\u003c\/h3\u003e\n\u003cp\u003eShips same day, carefully packaged and insured.\u003c\/p\u003e\n\u003ch3\u003eNote\u003c\/h3\u003e\n\u003cp\u003eInstallation should be performed by a qualified person in accordance with local codes. Always turn off the main breaker before working inside a panel.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":46726736871590,"sku":"BR230","price":36.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0708\/1377\/8086\/files\/57_2120e702-a11b-4279-b2d3-ccd709601101.png?v=1759771212"},{"product_id":"eaton-br220-20a-2pole-circuit-breaker","title":"Eaton BR220 20 Amp 2-Pole Circuit Breaker, Type BR Double-Pole 120\/240V","description":"\u003cp\u003eThe Eaton BR220 is a brand new 20 Amp, 2-pole, 120\/240V \u003cstrong\u003eType BR plug-on circuit breaker\u003c\/strong\u003e for Eaton BR load centers. It gives your 240V branch circuits reliable thermal-magnetic protection against overloads and short circuits.\u003c\/p\u003e\n\u003ch3\u003eSimple, Secure Plug-On Install\u003c\/h3\u003e\n\u003cp\u003eThe BR220 snaps straight onto the panel bus, with one pressure-plate terminal on each pole. It's a quick swap when replacing a worn breaker, and a solid choice when adding a new 240V circuit.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e20A, 2-pole (double-pole), 120\/240VAC\u003c\/li\u003e\n\u003cli\u003e10kA interrupting rating\u003c\/li\u003e\n\u003cli\u003eThermal-magnetic trip for overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003eHACR rated for heating, air conditioning, and refrigeration equipment\u003c\/li\u003e\n\u003cli\u003eCommon trip: both poles open together\u003c\/li\u003e\n\u003cli\u003ePlug-on mounting for Eaton Type BR load centers\u003c\/li\u003e\n\u003cli\u003eUL Listed\u003c\/li\u003e\n\u003cli\u003eBrand new\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSize\u003c\/h3\u003e\n\u003cp\u003eTakes 2 spaces (1\" per pole) in an Eaton BR load center.\u003c\/p\u003e\n\u003ch3\u003eUses\u003c\/h3\u003e\n\u003cp\u003e240V baseboard heaters, small A\/C units and heat pumps, well pumps, and other 20A, 240V circuits.\u003c\/p\u003e\n\u003ch3\u003eMost Common Use\u003c\/h3\u003e\n\u003cp\u003eElectric baseboard heater and small 240V equipment circuits in homes with an Eaton BR panel, or replacing a worn or faulty 20A 2-pole breaker.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e A 20A breaker must be used with 12 AWG copper wire or larger.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e This breaker is designed for \u003cstrong\u003eEaton Type BR load centers\u003c\/strong\u003e. Check the label inside your panel door before ordering. If you're unsure, send us a photo of your panel label and we'll help you confirm the fit.\u003c\/p\u003e\n\u003ch3\u003eWhy Buy From Us\u003c\/h3\u003e\n\u003cp\u003eWith 24+ years of experience in the electrical industry, we know the products we sell and we're happy to answer your questions before you buy. Same-day handling, insured shipping, 30-day returns, and a 12-month warranty handled directly by us.\u003c\/p\u003e\n\u003ch3\u003eShipping\u003c\/h3\u003e\n\u003cp\u003eShips same day, carefully packaged and insured.\u003c\/p\u003e\n\u003ch3\u003eNote\u003c\/h3\u003e\n\u003cp\u003eInstallation should be performed by a qualified person in accordance with local codes. Always turn off the main breaker before working inside a panel.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":46726736904358,"sku":"BR220","price":23.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0708\/1377\/8086\/files\/57_46274524-c514-4cc8-8c4e-eff54d6b14d1.png?v=1759771220"},{"product_id":"eaton-br225-25a-2pole-circuit-breaker","title":"Eaton BR225 25 Amp 2-Pole Circuit Breaker, Type BR Double-Pole 120\/240V","description":"\u003cp\u003eThe Eaton BR225 is a brand new 25 Amp, 2-pole, 120\/240V \u003cstrong\u003eType BR plug-on circuit breaker\u003c\/strong\u003e for Eaton BR load centers. It gives your 240V branch circuits reliable thermal-magnetic protection against overloads and short circuits.\u003c\/p\u003e\n\u003ch3\u003eThe Right Size for the Job\u003c\/h3\u003e\n\u003cp\u003eSome equipment calls for a 25A breaker, like many A\/C condensers and heat pumps whose nameplate lists a 25A maximum. The BR225 lets you match the equipment exactly instead of guessing.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e25A, 2-pole (double-pole), 120\/240VAC\u003c\/li\u003e\n\u003cli\u003e10kA interrupting rating\u003c\/li\u003e\n\u003cli\u003eThermal-magnetic trip for overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003eHACR rated for heating, air conditioning, and refrigeration equipment\u003c\/li\u003e\n\u003cli\u003eCommon trip: both poles open together\u003c\/li\u003e\n\u003cli\u003ePlug-on mounting for Eaton Type BR load centers\u003c\/li\u003e\n\u003cli\u003eUL Listed\u003c\/li\u003e\n\u003cli\u003eBrand new\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSize\u003c\/h3\u003e\n\u003cp\u003eTakes 2 spaces (1\" per pole) in an Eaton BR load center.\u003c\/p\u003e\n\u003ch3\u003eUses\u003c\/h3\u003e\n\u003cp\u003eA\/C condensers, heat pumps, water heaters, and other 25A, 240V circuits.\u003c\/p\u003e\n\u003ch3\u003eMost Common Use\u003c\/h3\u003e\n\u003cp\u003eA\/C and heat pump circuits where the equipment nameplate calls for a 25A breaker, in homes with an Eaton BR panel. Always follow the equipment nameplate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e A 25A breaker must be used with 10 AWG copper wire or larger.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e This breaker is designed for \u003cstrong\u003eEaton Type BR load centers\u003c\/strong\u003e. Check the label inside your panel door before ordering. If you're unsure, send us a photo of your panel label and we'll help you confirm the fit.\u003c\/p\u003e\n\u003ch3\u003eWhy Buy From Us\u003c\/h3\u003e\n\u003cp\u003eWith 24+ years of experience in the electrical industry, we know the products we sell and we're happy to answer your questions before you buy. Same-day handling, insured shipping, 30-day returns, and a 12-month warranty handled directly by us.\u003c\/p\u003e\n\u003ch3\u003eShipping\u003c\/h3\u003e\n\u003cp\u003eShips same day, carefully packaged and insured.\u003c\/p\u003e\n\u003ch3\u003eNote\u003c\/h3\u003e\n\u003cp\u003eInstallation should be performed by a qualified person in accordance with local codes. Always turn off the main breaker before working inside a panel.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":46726736969894,"sku":"BR225","price":23.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0708\/1377\/8086\/files\/57_dedc82a5-8594-46cb-bf13-a173ecb7e71f.png?v=1759771227"},{"product_id":"square-d-qo115-15a-1-pole-circuit-breaker","title":"Square D QO115 15 Amp Single-Pole Circuit Breaker, QO Plug-On 120\/240V","description":"\u003cp\u003eThe Square D QO115 by Schneider Electric is a 15 Amp, 1-pole, 120\/240VAC plug-on circuit breaker for Square D QO load centers. It gives your branch circuits reliable thermal-magnetic protection against overloads and short circuits, and it's the standard 15A breaker for lighting and receptacle circuits in homes with a QO panel.\u003c\/p\u003e\n\u003ch3\u003eVisi-Trip: Know Which Breaker Tripped\u003c\/h3\u003e\n\u003cp\u003eWhen a QO breaker trips, a bright red indicator pops into the window on the front. No more flipping every breaker in the panel to find the one that tripped. You see it at a glance.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e15A, 1-pole, 120\/240VAC, 10kA interrupting rating\u003c\/li\u003e\n\u003cli\u003eThermal-magnetic trip for overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003eVisi-Trip red indicator shows when the breaker has tripped\u003c\/li\u003e\n\u003cli\u003eHACR rated for air conditioning, heating, and refrigeration equipment\u003c\/li\u003e\n\u003cli\u003eSWD (switching duty) rated for switching 120V fluorescent lighting loads\u003c\/li\u003e\n\u003cli\u003ePressure plate terminal accepts 14 to 8 AWG copper or aluminum wire\u003c\/li\u003e\n\u003cli\u003ePlug-on mounting: snaps onto the panel bus\u003c\/li\u003e\n\u003cli\u003eUL Listed and CSA Certified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSize\u003c\/h3\u003e\n\u003cp\u003e3\/4\" wide, 3\" tall, and 2 15\/16\" deep. It takes one space in the panel, the same as any standard QO 1-pole breaker.\u003c\/p\u003e\n\u003ch3\u003eUses\u003c\/h3\u003e\n\u003cp\u003eGeneral lighting and receptacle circuits, bathroom fans, garage lighting, and other 15A, 120V branch circuits wired with 14 AWG copper.\u003c\/p\u003e\n\u003ch3\u003eMost Common Use\u003c\/h3\u003e\n\u003cp\u003eReplacing a worn or faulty 15A breaker, or adding a new lighting or receptacle circuit, in a Square D QO load center.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e This breaker fits \u003cstrong\u003eSquare D QO load centers and NQ\/NQOD panelboards\u003c\/strong\u003e. It does \u003cstrong\u003enot\u003c\/strong\u003e fit Square D Homeline panels or panels from other brands. Check the label inside your panel door before ordering. If you're unsure, send us a photo of your panel label and we'll help you confirm the fit.\u003c\/p\u003e\n\u003ch3\u003eWhy Buy From Us\u003c\/h3\u003e\n\u003cp\u003eWith 24+ years of experience in the electrical industry, we know the products we sell and we're happy to answer your questions before you buy. Same-day handling, insured shipping, 30-day returns, and a 12-month warranty handled directly by us.\u003c\/p\u003e\n\u003ch3\u003eShipping\u003c\/h3\u003e\n\u003cp\u003eShips same day, carefully packaged and insured.\u003c\/p\u003e\n\u003ch3\u003eNote\u003c\/h3\u003e\n\u003cp\u003eInstallation should be performed by a qualified person in accordance with local codes. Always turn off the main breaker before working inside a panel.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":57574136774822,"sku":"QO115","price":9.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0708\/1377\/8086\/files\/1_239bd7e6-3537-426f-8958-49dc6a488627.png?v=1791240587"},{"product_id":"square-d-qo120-20a-1-pole-circuit-breaker","title":"Square D QO120 20 Amp Single-Pole Circuit Breaker, QO Plug-On 120\/240V","description":"\u003cp\u003eThe Square D QO120 by Schneider Electric is a 20 Amp, 1-pole, 120\/240VAC plug-on circuit breaker for Square D QO load centers. It gives your branch circuits reliable thermal-magnetic protection against overloads and short circuits, and it's the go-to 20A breaker for kitchen, bathroom, laundry, and garage receptacle circuits in homes with a QO panel.\u003c\/p\u003e\n\u003ch3\u003eVisi-Trip: Know Which Breaker Tripped\u003c\/h3\u003e\n\u003cp\u003eWhen a QO breaker trips, a bright red indicator pops into the window on the front. No more flipping every breaker in the panel to find the one that tripped. You see it at a glance.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e20A, 1-pole, 120\/240VAC, 10kA interrupting rating\u003c\/li\u003e\n\u003cli\u003eThermal-magnetic trip for overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003eVisi-Trip red indicator shows when the breaker has tripped\u003c\/li\u003e\n\u003cli\u003eHACR rated for air conditioning, heating, and refrigeration equipment\u003c\/li\u003e\n\u003cli\u003eSWD (switching duty) rated for switching 120V fluorescent lighting loads\u003c\/li\u003e\n\u003cli\u003ePressure plate terminal accepts 14 to 8 AWG copper or aluminum wire\u003c\/li\u003e\n\u003cli\u003ePlug-on mounting: snaps onto the panel bus\u003c\/li\u003e\n\u003cli\u003eUL Listed and CSA Certified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSize\u003c\/h3\u003e\n\u003cp\u003e3\/4\" wide, 3\" tall, and 2 15\/16\" deep. It takes one space in the panel, the same as any standard QO 1-pole breaker.\u003c\/p\u003e\n\u003ch3\u003eUses\u003c\/h3\u003e\n\u003cp\u003eKitchen countertop receptacles, bathroom circuits, laundry rooms, garages, dishwashers, disposals, microwaves, and other 20A, 120V branch circuits wired with 12 AWG copper.\u003c\/p\u003e\n\u003ch3\u003eMost Common Use\u003c\/h3\u003e\n\u003cp\u003eKitchen and bathroom receptacle circuits, which the NEC requires to be 20A, or replacing a worn or faulty 20A breaker in a Square D QO load center.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e A 20A breaker must be used with 12 AWG copper wire or larger. Never install a 20A breaker on a circuit wired with 14 AWG wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e This breaker fits \u003cstrong\u003eSquare D QO load centers and NQ\/NQOD panelboards\u003c\/strong\u003e. It does \u003cstrong\u003enot\u003c\/strong\u003e fit Square D Homeline panels or panels from other brands. Check the label inside your panel door before ordering. If you're unsure, send us a photo of your panel label and we'll help you confirm the fit.\u003c\/p\u003e\n\u003ch3\u003eWhy Buy From Us\u003c\/h3\u003e\n\u003cp\u003eWith 24+ years of experience in the electrical industry, we know the products we sell and we're happy to answer your questions before you buy. Same-day handling, insured shipping, 30-day returns, and a 12-month warranty handled directly by us.\u003c\/p\u003e\n\u003ch3\u003eShipping\u003c\/h3\u003e\n\u003cp\u003eShips same day, carefully packaged and insured.\u003c\/p\u003e\n\u003ch3\u003eNote\u003c\/h3\u003e\n\u003cp\u003eInstallation should be performed by a qualified person in accordance with local codes. Always turn off the main breaker before working inside a panel.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":57578631954598,"sku":"QO120","price":10.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0708\/1377\/8086\/files\/1_200e4f7e-0b0a-499f-87de-0bd95a99dec6.png?v=1791291785"},{"product_id":"eaton-pdg23m0050tffl-50a-3-pole-power-defense-mccb","title":"Eaton PDG23M0050TFFL 50 Amp 3-Pole Power Defense Molded Case Circuit Breaker, Frame 2, 65kA @ 480V","description":"\u003cp\u003eThe Eaton PDG23M0050TFFL is a brand new, factory-sealed \u003cstrong\u003e50 Amp, 3-pole Power Defense molded case circuit breaker (MCCB)\u003c\/strong\u003e, Frame 2, globally rated and rated 65kA at 480V. It is built for industrial and commercial power distribution, feeder protection, and equipment panels.\u003c\/p\u003e\n\u003ch3\u003ePower Defense: Eaton's Current MCCB Platform\u003c\/h3\u003e\n\u003cp\u003ePower Defense is Eaton's modern molded case breaker line. The PDG2 (Frame 2) is a compact, globally rated breaker certified to UL 489, CSA, IEC 60947-2, and CCC, so the same breaker works in North American and international equipment.\u003c\/p\u003e\n\u003ch3\u003eHigh Interrupting Rating\u003c\/h3\u003e\n\u003cp\u003eThe \"M\" interrupting rating gives you 65kAIC at 480V and 100kAIC at 240V (UL), and 35kAIC at 600V (UL\/CSA). That covers most commercial and light industrial systems with high available fault current.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e50A, 3-pole, 600VAC maximum\u003c\/li\u003e\n\u003cli\u003eInterrupting ratings: 65kA @ 480V, 100kA @ 240V, 35kA @ 600V (UL)\u003c\/li\u003e\n\u003cli\u003eThermal-magnetic trip unit, fixed thermal \/ fixed magnetic (T-M Fxd-Fxd)\u003c\/li\u003e\n\u003cli\u003eStandard terminals on the load side only (TFFL)\u003c\/li\u003e\n\u003cli\u003eFrame 2 (PD2 Global), Class A\u003c\/li\u003e\n\u003cli\u003eUL 489, CSA, IEC 60947-2, CCC Marked, RoHS compliant\u003c\/li\u003e\n\u003cli\u003eCompatible with Eaton PDG2 Frame 2 accessories (handles, shunt trips, aux switches, terminal kits)\u003c\/li\u003e\n\u003cli\u003eBrand new in original Eaton box, factory sealed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCatalog number: PDG23M0050TFFL\u003c\/li\u003e\n\u003cli\u003eUPC: 786679862285\u003c\/li\u003e\n\u003cli\u003eSize: about 4.1\" wide x 6\" tall x 3.5\" deep (104.6 x 152.4 x 88.9 mm)\u003c\/li\u003e\n\u003cli\u003eWeight: about 4 lb (1.82 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eUses\u003c\/h3\u003e\n\u003cp\u003eIndustrial control panels, commercial switchboards and panelboards, motor and equipment feeders, HVAC and machinery disconnects, and OEM equipment that calls for a 50A, 3-pole Eaton Power Defense Frame 2 breaker.\u003c\/p\u003e\n\u003ch3\u003eWhat's in the Box\u003c\/h3\u003e\n\u003cp\u003eOne (1) Eaton PDG23M0050TFFL breaker, mounting hardware, and Eaton installation instructions, as shipped by the factory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Please match the full catalog number, frame, and terminal configuration to your equipment before ordering. Load-side-only terminals (TFFL) are standard on this model. If you're unsure, send us a photo of your existing breaker label or panel schedule and we'll help you confirm the fit.\u003c\/p\u003e\n\u003ch3\u003eWhy Buy From Us\u003c\/h3\u003e\n\u003cp\u003eWith 24+ years of experience in the electrical industry, we know the products we sell and we're happy to answer your questions before you buy. Same-day handling, insured shipping, 30-day returns, and a 12-month warranty handled directly by us.\u003c\/p\u003e\n\u003ch3\u003eShipping\u003c\/h3\u003e\n\u003cp\u003eShips same day, carefully packaged and insured.\u003c\/p\u003e\n\u003ch3\u003eNote\u003c\/h3\u003e\n\u003cp\u003eInstallation should be performed by a qualified electrician in accordance with the NEC and local codes. Always de-energize and lock out equipment before working on it.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":57644676219046,"sku":"PDG23M0050TFFL","price":499.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0708\/1377\/8086\/files\/image.png?v=1792011342"}],"url":"https:\/\/myelectricstore.shop\/collections\/regular-breakers.oembed","provider":"My Electric Store ","version":"1.0","type":"link"}